Site Master
S331D/S332D
Specifications
MS2712
SiteMaster
SpectrumMaster
CellMaster
S331D
Site Master
SiteMaster
MS2712
MS2711D
Spectrum Master
SpectrumMaster
MS2712
MT8212A
Cell Master
CellMaster
Ordering Information
Connection Configurations:
Terminate (75, 120)
Bridge (1000)
Monitor (Connect via 20 dB pad in DSX)
Receiver Sensitivity: 0 to –43 dB
Clock Sources: External
Internal 2.048 MHz ±30 ppm
Pulse Shapes: Conform to ITU G.703
Pattern Generation and Detection:
PRBS: 2-9, 2-11, 2-15, 2-20, 2-23 Inverted and
non-inverted, QRSS, 1-in-8 (1-in-7), 2-in-8, 3-in-24,
All ones, All zeros, T1-Daly, User defined (32 bits)
Circuit Status Reports: Carrier present, Frame ID
and Sync., Pattern ID and Sync.
Alarm Detection: AIS, RAI, MMF
Error Detection: Frame Bits, Bit, BER, BPV, CRC, E-Bits,
Error Sec
Error Insertion: Bit, BPV, Framing Bits, RAI, AIS
Loopback Modes: Self loopback
Level Measurements: Vp-p (±5%)
Data Log: Continuous, up to 48 hrs
General
Language Support: Chinese, English, French, German,
Japanese, Spanish,
Internal Trace Memory: 200 traces
Setup Configuration: S332D - 20, S331D - 25
Display: VGA monochrome or VGA color LCD (Option 3)
with adjustable backlight
Inputs and Outputs Ports:
RF Out: Type N, female, 50
Maximum Input without Damage: +23 dBm, ± 50 VDC
RF In: Type N, female, 50
Maximum Input without Damage: +43 dBm (Peak), ± 50 VDC
Ext. Trig In: BNC, female (5 V TTL) (S332D Models only)
Ext. Freq Ref In (2 to 20 MHz): Shared BNC, female,
50, (–15 dBm to +10 dBm) (S332D Models only)
T1/E1 (Receive & Transmit): Bantam Jack
(S331D Models with Option 50 only)
Serial Interface: RS-232 9 pin D-sub, three wire serial
Electromagnetic Compatibility: Meets European
Community requirements for CE marking
Safety: Conforms to EN 61010-1 for Class 1
portable equipment
Temperature:
Operating: –10°C to 55°C, humidity 85% or less
Non-operating: –51°C to +71°C (recommended
battery to store separately between 0°C to +40°C
for any prolonged non-operating storage period)
Environmental: MIL-PRF-28800F Class 2
Power Supply:
External DC Input: +12.5 to +15 volt dc, 1350 mA max
Internal: NiMH battery: 10.8 volts, 1800 mAH
Dimensions:
Size (w x h x d): 25.4 cm x 17.8 cm x 6.1 cm
(10.0 in x 7.0 in x 2.4 in)
Weight: <2.28 kg (<5 lbs) includes battery
Measurement Range: +20 dBm to –135 dBm
Input Attenuator Range: 0 to 51 dB,
selected manually or automatically coupled to
the reference level. Resolution in 1 dB steps.
Displayed Average Noise Level:
–135 dBm typical, 10 MHz (preamp on)
–115 dBm typical, <10 MHz (preamp on)
for input terminated , 0 dB attenuation,
RMS detection, 100 Hz RBW
Dynamic Range: >65 dB
Display Range: 1 to 15 dB/division, in 1 dB
steps, 10 divisions displayed
Scale Units: dBm, dBV, dBmV, dBuV, V, W
RF Input VSWR: 1.5:1 typical, (20 dB atten.,
(10 MHz to 2.4 GHz)
Power Meter (Option 29)
Frequency Range: 3 MHz to 3.0 GHz
Measurement Range: –80 dBm to +20 dBm
Display Range: –80 dBm to +80 dBm
Offset Range: 0 to +60 dB
Accuracy: ±1 dB typical (±1.5 dBm max), >2 GHz to 3 GHz
±0.5 dB typical (±1 dB max), 10 MHz to 2 GHz
±2 dB, 3 MHz to <10 MHz
VSWR: 1.5:1 typical (Pin> -30 dBm, 10 MHz to 2.4 GHz)
Maximum Power: +20 dBm (0.1W) without external
attenuator
T1 Analyzer (Option 50 on
S331D Models only)
Line Coding: AMI, B8ZS
Framing Modes: D4 (Superframe), ESF
(Extended Superframe)
Connection Configurations:
Terminate (100)
Bridge (1000)
Monitor (Connect via 20 dB pad in DSX)
Receiver Sensitivity: 0 to –36 dBdsx
Transmit Level: 0 dB, –7.5 dB, and -15 dB
Clock Sources: External
Internal: 1.544 MHz ± 30 ppm
Pulse Shapes: Conform to ANSI T1.403
Pattern Generation and Detection: PRBS: 2-9, 2-11,
2-15, 2-20, 2-23 Inverted and non-inverted,
QRSS, 1-in-8 (1-in-7), 2-in-8, 3-in-24, All ones,
All zeros, T1-Daly, User defined (32 bits)
Circuit Status Reports: Carrier present, Frame ID
and Sync., Pattern ID and Sync.
Alarm Detection: AIS (Blue Alarm), RAI
(Yellow Alarm)
Error Detection: Frame Bits, Bit, BER, BPV, CRC,
Error Sec
Error Insertion: Bit, BPV, Framing Bits, RAI, AIS
Loopback Modes: Self loop, CSU, NIU, User
defined, In-band or Data Link
Level Measurements: Vp-p (± 5%)
Data Log: Continuous, up to 48 hrs
E1 Analyzer (Option 50 on
S331D Models only)
Line Coding: AMI, HDB3
Framing Modes: PCM30, PCM30CRC, PCM31,
PCM31CRC
All specifications apply when the unit is
calibrated at ambient temperature after a five
minute warm up. Typical values are given for
reference, and are not guaranteed.
Cable and Antenna Analyzer
Frequency Range: 25 MHz to 4.0 GHz
Frequency Accuracy: ±75 ppm @ +25˚C
Frequency Resolution: 100 kHz
Output Power: <0 dBm (–10 dBm nominal)
Immunity to Interfering Signals:
on-channel +17 dBm
on-frequency –5 dBm
Measurement speed: 3.5 msec / data point (CW ON)
Number of data points: 130, 259, 517
Return Loss: Range: 0.00 to 60.00 dB
Resolution: 0.01 dB
VSWR: Range: 1.00 to 65.00
Resolution: 0.01
Cable Loss: Range: 0.00 to 30.00 dB
Resolution: 0.01 dB
Measurement Accuracy: >42 dB corrected directivity
after calibration
Distance-To-Fault
Vertical Range: Return Loss: 0.00 to 60.00 dB
VSWR: 1.00 to 65.00
Horizontal Range: Range: 0 to (# of data pts –1) x
Resolution to a maximum of 1197 m (3929 ft),
# of data pts = 130, 259, 517
Horizontal Resolution (Rectangular windowing):
Resolution (meter) = (1.5 x 10^8) x (Vp)/DF
Where Vp is the cable's relative propagation
velocity and where DF is the stop frequency minus
the start frequency (in Hz)
Spectrum Analyzer (S332D Models)
Frequency:
Frequency Range: 100 kHz to 3.0 GHz
Measurement Range: +20 dBm to –135 dBm
Frequency Reference (Internal Timebase):
Aging: ±1 ppm/yr
Accuracy: ±2 ppm
Frequency Span: 10 Hz to 2.99 GHz in 1, 2, 5
step selections in auto mode, plus zero span
Sweep Time: 1.1 sec full span;
50 µsec to 20 sec selectable in zero span
Resolution Bandwidth (–3 dB):
100 Hz to 1 MHz in 1-3 sequence ± 5% Accuracy
Video Bandwidth (–3 dB):
3 Hz to 1 MHz in 1-3 sequence ± 5% Accuracy
SSB Phase Noise (1 GHz) @ 30 kHz Offset:
–75 dBc/Hz
Spurious Responses: –45 dBc
Spurious Residual Responses: –90dBm, >10 MHz
–80 dBm, 10 MHz (10 kHz RBW, pre-amp on)
Amplitude:
Total Level Accuracy:
±1 dB typical (±1.5 dBm max), >2 GHz to 3 GHz
±0.5 dB typical (±1 dB max), 10 MHz to 2 GHz
±2 dB, 500 kHz to <10 MHz
±3 dB typical, <500 kHz
for input signal levels –60 dBm,
excludes input VSWR mismatch
Discover What’s Possible
®
©Anritsu October 2003. All trademarks are registered trademarks of
their respective companies. Data is subject to change without notice.
PN: 11410-00321, Rev. A
Site Master
S331D/S332D
SiteMaster
The Worlds Leading Cable and Antenna System Analyzer
SALES CENTERS:
United States (800) ANRITSU Europe 44 (0) 1582-433433 Microwave Measurements Division
Canada (800) ANRITSU Japan 81 (46) 223-1111 490 Jarvis Drive, Morgan Hill, CA 95037-2809
South America 55 (21) 2527-6922 Asia-Pacific (65) 6282-2400 http://www.us.anritsu.com
Basic Models
S331D Cable and Antenna Analyzer (25 MHz to 4.0 GHz)
with built-in DTF
S332D Cable and Antenna Analyzer (25 MHz to 4.0 GHz),
with built-in DTF, Spectrum Analyzer (100 kHz to 3.0 GHz)
Standard Accessories Include
User's Guide
Soft Carrying Case
AC-DC Adapter with Power Cord
Automotive Cigarette Lighter/12 Volt DC Adapter
One Year Warranty
Handheld Software Tools CDROM containing Fault Location (DTF)
and Smith Chart
Serial Interface Cable
Rechargeable Battery, NiMH
Options
Option 3 Color LCD Display
Option 29 Power Meter (does not require external detector)
Option 50 T1/E1 Analyzer (S331D only)
Optional Accessories
1N50C Limiter, N(m) to N(f), 50, 10 MHz to 18 GHz
42N50-20 Attenuator, 20 dB, 5 watt, DC to 18 GHz, N(m)-N(f)
42N50A-30 Attenuator, 30 dB, 50 watt, DC to 18 GHz, N(m)-N(f)
ICN50 InstaCal
Calibration Module, 2 MHz to 4.0 GHz, N(m), 50
22N50 Open/Short, DC to 18 GHz, N(m), 50
22NF50 Open/Short, DC to 18 GHz, N(f), 50
SM/PL Precision Load, DC to 4 GHz, 42 dB, N(m), 50
SM/PLNF Precision Load, DC to 4 GHz, 42 dB, N(f), 50
OSLN50LF Precision Open/Short/Load, DC to 4 GHz, 42 dB, 50, N(m)
OSLNF50LF Precision Open/Short/Load, DC to 4 GHz, 42 dB, 50, N(f)
2000-767 Precision Open/Short/Load, DC to 4 GHz, 7/16 DIN(m), 50
2000-768 Precision Open/Short/Load, DC to 4 GHz, 7/16 DIN(f), 50
15NN50-1.5C Test Port Cable Armored, 1.5 meters, N(m)-N(m), 6 GHz, 50
15NN50-3.0C Test Port Cable Armored, 3.0 meters, N(m)-N(m), 6 GHz, 50
15NN50-5.0C Test Port Cable Armored, 5.0 meters, N(m)-N(m), 6 GHz, 50
15NNF50-1.5C Test Port Cable Armored, 1.5 meters, N(m)-N(f), 6 GHz, 50
15NNF50-3.0C Test Port Cable Armored, 3.0 meters, N(m)-N(f), 6 GHz, 50
15NNF50-5.0C Test Port Cable Armored, 5.0 meters, N(m)-N(f), 6 GHz, 50
15ND50-1.5C Test Port Cable Armored, 1.5 meters, N(m)-7/16 DIN(m),
6 GHz, 50
15NDF50-1.5C Test Port Cable Armored, 1.5 meters, N(m)-7/16 DIN(f),
6 GHz, 50
34NN50A Precision Adapter, N(m)-N(m), DC to 18 GHz, 50
34NFNF50 Precision Adapter, N(f)-N(f), DC to 18 GHz, 50
1091-26 Adapter, N(m)-SMA(m), DC to 18 GHz, 50
1091-27 Adapter, N(m)-SMA(f), DC to 18 GHz, 50
1091-80 Adapter, N(f)-SMA(m), DC to 18 GHz, 50
1091-81 Adapter, N(f)-SMA(f), DC to 18 GHz, 50
1091-172 Adapter, N(m)-BNC(f), DC to 1.3 GHz, 50
510-90 Adapter, 7/16 DIN(f)-N(m), DC to 7.5 GHz, 50
510-91 Adapter, 7/16 DIN(f)-N(f), DC to 7.5 GHz, 50
510-92 Adapter, 7/16 DIN(m)-N(m), DC to 7.5 GHz, 50
510-93 Adapter, 7/16 DIN(m)-N(f), DC to 7.5 GHz, 50
510-96 Adapter, 7/16 DIN(m)-7/16 DIN(m), DC to 7.5 GHz, 50
510-97 Adapter, 7/16 DIN(f)-7/16 DIN(f), DC to 7.5 GHz, 50
2000-1030 Portable Antenna, SMA (m), 1.71 to 1.88 GHz, 50
2000-1031 Portable Antenna, SMA (m), 1.85 to 1.99 GHz, 50
2000-1032 Portable Antenna, SMA (m), 2.4 to 2.5 GHz, 50
2000-1200 Portable Antenna, SMA (m), 806-869 MHz, 50
2000-1035 Portable Antenna, SMA (m), 896-941 MHz, 50
1030-86 Band Pass Filter, 806-869 MHz, 1.7 dB loss, N(m) to SMA(f), 50
1030-87 Band Pass Filter, 902-960 MHz, 1.7 dB loss, N(m) to SMA(f), 50
1030-88 Band Pass Filter, 1.85-1.99 GHz, 1.8 dB loss, N(m) to SMA(f), 50
1030-89 Band Pass Filter, 2.4-2.5 GHz, 1.4 dB loss, N(m) to SMA(f), 50
806-16 Bantam Plug to Bantam Plug
806-116 Bantam Plug to BNC
806-117 Bantam "Y" Plug to RJ48
551-1691 USB to RS232 adapter cable
48258 Soft Carrying Case
760-229 Transit Case
633-27 Rechargeable Battery, NiMH
2000-1029 Battery Charger, NiMH, w/ Universal Power Supply
40-163 AC/DC Adapter
806-62 Automotive Cigarette Lighter/12 Volts DC Adapter
800-441 Serial Interface Cable
2300-347 Software Tools
10580-00079 Site Master S331D/S332D User's Guide
10580-00100 Site Master S331D/S332D Programming Manual
10580-00101 Site Master S331D Maintenance Manual
10580-00102 Site Master S332D Maintenance Manual
Printers
2000-1214 HP DeskJet Printer, Model 450: Includes printer cable, 2000-1216
black print cartridge and U.S. power cord. Also includes 2000-753
serial-to-parallel Centronics converter cable and 1091-310
Centronics-to DB25 adapter. Rechargeable battery is optional and
is not included.
2000-753 Null Modem Serial-to-Parallel Centronics Converter Cable
1091-310 Adapter 36-pin Centronics female-to-DB25 female
2000-1216 Black Print Cartridge
2000-663 Power Cable (Europe) for DeskJet Printer
2000-664 Power Cable (Australia) for DeskJet Printer
2000-667 Power Cable (S. Africa) for DeskJet Printer
2000-1217 Rechargeable Battery for DeskJet Printer, Model 450
2000-1218 Power Cable (U.K.) for DeskJet Printer
Cable and Antenna Analyzer
25 MHz to 4000 MHz
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Site Master

Site Master™S331D/S332DSpecificationsMS2712SiteMasterSpectrumMasterCellMasterS331D Site MasterSiteMasterMS2712MS2711D Spectrum MasterSpectrumMasterMS2

Page 2 - Test / Capability Benefits

Site Master is the preferred cable and antenna analyzer of wireless providers, contractors and installers.Cable and Antenna AnalyzerThe cable and ante

Page 3

Site Master is the preferred cable and antenna analyzer of wireless providers, contractors and installers.Cable and Antenna AnalyzerThe cable and ante

Page 4

Site Master is the preferred cable and antenna analyzer of wireless providers, contractors and installers.Cable and Antenna AnalyzerThe cable and ante

Page 5

Site Master™S331D/S332DSpecificationsMS2712SiteMasterSpectrumMasterCellMasterS331D Site MasterSiteMasterMS2712MS2711D Spectrum MasterSpectrumMasterMS2

Page 6

Site Master™S331D/S332DSpecificationsMS2712SiteMasterSpectrumMasterCellMasterS331D Site MasterSiteMasterMS2712MS2711D Spectrum MasterSpectrumMasterMS2

Comments to this Manuals

No comments