Anritsu Site Master S331D User Manual

Browse online or download User Manual for Measuring instruments Anritsu Site Master S331D. Anritsu Site Master S331D User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 132
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Site Master is the preferred cable and antenna analyzer of
wireless providers, contractors and installers.
Site Master
S331D/S332D
Cable and Antenna Analyzer
MS2712
MS2712
MS2712
SiteMaster
SpectrumMaster
CellMaster
MS2711D
Spectrum Master
S331D
Site Master
SiteMaster
SpectrumMaster
MT8212A
Cell Master
CellMaster
Color display option shown
Programming Manual
Page view 0
1 2 3 4 5 6 ... 131 132

Summary of Contents

Page 1 - Site Master

Site Master is the preferred cable and antenna analyzer ofwireless providers, contractors and installers.Site Master™S331D/S332DCable and Antenna Anal

Page 2 - March 2004 10580-00100

Control Byte#Name DescriptionWatchdogTimer42 (2Ah) Power Meter Offset Mode Enables or disables Power Meter offset Yes43 (2Bh) Power Meter Zero Mode En

Page 3 - Site Master PM i

Automatic control couples the attenuation to the reference level. Note that setting the attenuation using this commandautomatically sets the attenuati

Page 4 - ...73

Set Baud Rate – Control Byte #197 (C5h)Description: Set baud rate for this session. An invalid setting returns the baud rate to 9600.Bytes to Follow:

Page 5 - Site Master PM iii

Read ASCII Serial Number – Control Byte #225 (E1h)Description: Reads and returns the Site Master serial number as 8 ASCII bytes.Bytes to Follow: 1 byt

Page 6

1) Clock Source00h: Internal01h: ExternalSite Master Returns: 1 byte1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Invalid clock sourc

Page 7 - Programming Overview

1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Invalid error type or value238 (EEh) Time Out ErrorSet T1/E1 Framing Mode – Control Wor

Page 8 - 2 Site Master PM

or1) 238 (EEh) Time Out ErrorGet T1/E1 Frame Sync Status – Control Word (A009h) (Option 50 only)Description: Get the frame sync status of T1 /E1.Bytes

Page 9 - Control Byte Summary

12) CRC (lower byte)T1:13) Errored Seconds (highest byte)14) Errored Seconds15) Errored Seconds16) Errored Seconds (lowest byte)E1:13) E Bits (higher

Page 10 - 4 Site Master PM

Bytes to Follow: 0 bytesSite Master Returns: 3 bytes1) Volts peak-to-peak (higher byte)2) Volts peak-to-peak (lower byte)3) 255 (FFh) Operation Comple

Page 11 - Site Master PM 5

00h: Off01h: OnSite Master Returns: 1 byte1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Invalid status or not enough memory238 (EEh)

Page 12 - 6 Site Master PM

Site Master Returns: 1 byte1) Status Byte255 (FFh) Operation Complete ByteSelect SPA/Power Meter Signal Standard - Control Word (A103h)Description: Se

Page 13 - Control Byte Descriptions

Control Byte#Name DescriptionWatchdogTimer106 (6Ah)Set Spectrum AnalyzerResolution Bandwidth FreqSets the Spectrum Analyzer resolution BW frequency (o

Page 14 - 8 Site Master PM

Read External Module Serial Number – Control Word (A202h) (Option 6 only)Description: Sets the serial number of the attached external converter module

Page 15 - Site Master PM 9

1) Fail Counter (higher byte)2) Fail Counter (lower byte)3) 255 (FFh) Operation Complete Byteor1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter

Page 16 - 10 Site Master PM

24) VNA Integration Test - Reserved25) SPA LO Test - Status (01h: Pass, 00h: Fail, FFh: SPA board not installed)26) SPA LO Test - Failed data point #2

Page 17 - Site Master PM 11

18) H/W Config - T1E1 COLD ID19) VNA PLL Lock Failure Test - Status (01h: Pass, 00h: Fail)20) VNA PLL Lock Failure Test - Failed data point # (Ignore

Page 18 - 12 Site Master PM

Programming ExamplesThis section contains several sample functions written in C, (and one in Visual Basic) that can be used as references whenprogramm

Page 19 - Site Master PM 13

/*********************************************************************//* unsigned char SetSPAScale(unsigned long ReferenceLevel, *//* unsigned long d

Page 20 - 14 Site Master PM

WriteToPort (SendScalePointer, 9);// Expecting 1 byte back (give the unit 5 seconds to respond):// 0xFF = success// 0xE0 = parameter failure (invalid

Page 21 - Site Master PM 15

/*********************************************************************//* unsigned char ExitRemote(BYTE *ResponseBytes) *//* Description: This functio

Page 22 - 16 Site Master PM

/*********************************************************************//* void Get8Bytes(unsigned long parm1, unsigned long parm2, *//* BYTE* ByteData

Page 23 - Site Master PM 17

/*********************************************************************//* BOOL OpenCommunications(int ComPort, int ComBaud) *//* Description : This fu

Page 24 - 18 Site Master PM

Control Byte#Name DescriptionWatchdogTimerA004hSet T1/E1 Error InsertType/ValueSets the Insertion Error type and the number of errors YesA005h Set T1/

Page 25 - Site Master PM 19

OPEN_EXISTING,0, // no overlapped I/ONULL); // null template/* Set up the COM Ports Input and Output BufferSyntax -BOOL SetupComm(HANDLE hFile, // han

Page 26 - 309-338) Not Used

case ‘3’:CommSettings.BaudRate = CBR_38400; // rate - 38400break;case ‘4’:CommSettings.BaudRate = CBR_56000; // rate - 56000break;case ‘5’:CommSetting

Page 27 - Site Master PM 21

NOTE: Without Timeout Settings, Reading the COM Port will not work properly*/// This gives the Timeout value for each bytes receivedtimeout.ReadInterv

Page 28 - 22 Site Master PM

Example in Visual BasicPrivate Sub cmdSetBaudRateSM_Click()Dim ChangeBaudSerialCmd As IntegerDim BaudRate As IntegerDim strInputBuf As VariantDim Prev

Page 29 - Site Master PM 23

GoTo SetSMBaud_err_handlerEnd IfIf Asc(strInputBuf) = 255 ThenMsgBox “Set Baud Rate Succesfully”ElseIf Asc(strInputBuf) = 238 ThenMsgBox “SiteMaster T

Page 30 - 24 Site Master PM

Parameter DefinitionsParameter # of bytes Step Example / DescriptionFrequency 4 bytes unsigned 1 Hz 1000.3 MHz = 1000300000Scale (RL, CL) 2 bytes unsi

Page 31 - Site Master PM 25

Spectrum Analyzer Signal StandardsIndex Standard Center Span Valid Channels00h AMPS / EIA 553 - Uplink 859000000 70000000 1-799, 990-102301h AMPS / EI

Page 32 - 26 Site Master PM

Index Standard Center Span Valid Channels27h ETACS - Uplink 916000000 88000000 0-1000, 1329-204728h ETACS - Downlink 916000000 88000000 0-1000, 1329-2

Page 33 - Site Master PM 27

Index Standard Center Span Valid Channels50h PHS - Downlink 1906500000 23000000 1-7751h SMR 800 - 12.5 kHz - Uplink 836000000 60000000 1-119952h SMR 8

Page 34 - 409-434) Not Used

VNA Signal StandardsIndex Standard Start Freq Stop Freq00h Bluetooth US & Europe Uplink 2400000000 248400000001h Bluetooth US & Europe Downlin

Page 35 - Site Master PM 29

Control Byte DescriptionsSetup System – Control Byte #1 (01h)Description: Sets system status flags and switches. The current value of the flags can be

Page 36 - 30 Site Master PM

Index Standard Start Freq Stop Freq27h ISM 2 4 GHZ Uplink 2400000000 248400000028h ISM 2 4 GHZ Downlink 2400000000 248400000029h ISM 2 4 GHZ Fullband

Page 37 - Site Master PM 31

Index Standard Start Freq Stop Freq50h SMR 1500 Fullband 1453000000 151300000051h TACS/ETACS Uplink+C22 872000000 91500000052h TACS ETACS Downlink 917

Page 39 - 292-321) Not Used

Select Measurement Mode – Control Byte #3 (03h)Description: Sets the measurement mode of the Site Master. The response byte will not be sent until the

Page 40 - 34 Site Master PM

Set Site Master VNA Marker – Control Byte #5 (05h)Description: Sets an individual marker position and status in the current VNA measurement mode. See

Page 41 - Site Master PM 35

Notes:Return Loss & Cable Loss:Limit should be sent as ( dB * 1000 )Maximum value sent is 60000 which represents 60.00 dBMinimum value sent is 0 w

Page 42 - 36 Site Master PM

Set Time/Date – Control Byte #8 (08h)Description: Sets the current time and date.This Time/Date is stamped into all stored sweeps (for users’ referenc

Page 43 - Site Master PM 37

Bytes to Follow: 1 byte1) Serial Port Echo Status00h = Off01h=OnSite Master Returns: 1 byte1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Err

Page 44 - 38 Site Master PM

Sequence Site Master Calibration – Control Byte #13 (0Dh)Description: Initiates a calibration step. The Site Master must be calibrated to give accurat

Page 45 - Site Master PM 39

WARRANTYThe Anritsu product(s) listed on the title page is (are) warranted against defects in materi-als and workmanship for one year from the date of

Page 46 - 40 Site Master PM

Store Sweep Trace – Control Byte #16 (10h)Description: Saves current trace to the next available memory location. Trace name can be set using control

Page 47 - Site Master PM 41

63) Stop Frequency64) Stop Frequency (lowest byte)65) Minimum Frequency Step Size (highest byte)66) Minimum Frequency Step Size67) Minimum Frequency S

Page 48 - 42 Site Master PM

164) Start Distance165) Start Distance166) Start Distance (lowest byte)167) Stop Distance (highest byte)168) Stop Distance169) Stop Distance170) Stop

Page 49 - 279) Reference Level Offset

bit 7 : Unit of Measurement (1b = Metric, 0b = English)194) Status Byte 4:(LSB) bit0-1:DTFWindowing Modebit: 1 0||0 0 - Rectangular (No Windowing)0 1

Page 50 - (lowest byte)

77) Ref Level18(highest byte)78) Ref Level79) Ref Level80) Ref Level (lowest byte)81) Scale per div19(highest byte)82) Scale per div83) Scale per div8

Page 51 - 47) Power Meter Offset

266) VBW Setting (Frequency in Hz)267) VBW Setting (Frequency in Hz)268) VBW Setting (Frequency in Hz) (lowest byte)269) OCC BW Method (0b if % of pow

Page 52 - 46 Site Master PM

300) Status Byte 5( 0b = Off/Beep if data is below line, 1b = On/Beep if data is above line)(LSB) bit 0 : Multiple Limit Upper Segment 3 Status On/Off

Page 53 - Site Master PM 47

Bytes to Follow: 1 byte1) Location to save system setup parameters:0 – 10 for SWR Mode, Return Loss Mode, Cable Loss Mode and DTF Mode0 – 5 for Spectr

Page 54 - 48 Site Master PM

3) Site Master Mode Data Points (lower byte)4) Start Frequency (Frequency in Hz) (highest byte)5) Start Frequency6) Start Frequency7) Start Frequency

Page 55 - Site Master PM 49

106) Start Distance (highest byte)36107) Start Distance108) Start Distance109) Start Distance (lowest byte)110) Stop Distance (highest byte)111) Stop

Page 56 - 50 Site Master PM

Table of ContentsProgramming Overview . . . . . . . . . . . . . . . . . . . . . . . . . ...1Control Byte Summary. . . . . . . . . . . . . . .

Page 57 - Site Master PM 51

152) Spectrum Analyzer Minimum Frequency Step Size (highest byte)153) Spectrum Analyzer Minimum Frequency Step Size154) Spectrum Analyzer Minimum Freq

Page 58 - 52 Site Master PM

340) RBW Setting (highest byte)47341) RBW Setting342) RBW Setting343) RBW Setting (lowest byte)344) VBW Setting (highest byte)48345) VBW Setting346) V

Page 59 - Site Master PM 53

bits6-7:NotUsed249) Status Byte 4: (0b = Off, 1b = On)(LSB) bit 0 : Not Usedbit 1 : Spectrum Analyzer Mode Marker 2 Delta On/Offbit 2 : Spectrum Analy

Page 60 - 54 Site Master PM

bit 5 : SPA Multiple Limit Upper Segment 1 Beep Level ABOVE/BELOW53bit 6 : SPA Multiple Limit Upper Segment 2 Status On/Offbit 7 : SPA Multiple Limit

Page 61 - Site Master PM 55

bit 5: Channel Power On/Offbit 6: Adjacent Channel Power On/Offbit 7: Not Used398) Printer Type55399) Current Language(0 = English, 1 = French, 2 = Ge

Page 62 - 301) Reference Level Offset

Notes:Battery Voltage in 1/10th of a Volt (e.g. 124 = 12.4 Volts)Temperature in 1/10th of degree Celsius (e.g., 362 = 36.2°C) or degree Fahrenheit (e.

Page 63 - Site Master PM 57

Upload SPA Sweep Trace – Control Byte #26 (1Ah)NOTE: This command exists for backward compatibility with the S33xC models. Features new to theS33xD mo

Page 64 - 78) Power Offset

71) Marker 2 (lower byte)72) Marker 3 (higher byte)73) Marker 3 (lower byte)74) Marker 4 (higher byte)75) Marker 4 (lower byte)76) Marker 5 (higher by

Page 65 - Site Master PM 59

262) Attenuation263) Attenuation264) Attenuation (lowest byte)265-280) Antenna Name (16 bytes in ASCII)281) Status Byte 1: (0b = Off, 1b = On)(LSB) bi

Page 66 - 60 Site Master PM

288) Reference Level Offset68(highest byte)289) Reference Level Offset290) Reference Level Offset291) Reference Level Offset (lowest byte)292-321) Not

Page 67 - Site Master PM 61

Upload Sweep Trace – Control Byte #36 (24h) ...62Get Options – Control Byte #37 (25h) ...71

Page 68 - 62 Site Master PM

48) Stop Frequency (highest byte)49) Stop Frequency50) Stop Frequency51) Stop Frequency (lowest byte)52) Minimum Frequency Step Size (highest byte)53)

Page 69 - Site Master PM 63

150) Start Distance (highest byte)76151) Start Distance152) Start Distance153) Start Distance (lowest byte)154) Stop Distance (highest byte)155) Stop

Page 70 - 64 Site Master PM

bit 5 : Cal On/Offbit 6 : Limit Type ( 0b = Single; 1b = Multiple)bit 7 : Unit of measurement (1b = Metric, 0b = English)181) Status Byte 4:(LSB) bit0

Page 71 - Site Master PM 65

1) Number of Following Bytes (higher byte)2) Number of Following Bytes (lower byte)3) Measurement Mode834) Printer Type845) Current Language(00h = Eng

Page 72 - 66 Site Master PM

56) Site Master VNA Single Limit (highest byte)8957) Site Master VNA Single Limit58) Site Master VNA Single Limit59) Site Master VNA Single Limit (low

Page 73 - Site Master PM 67

156) Cable Loss157) Cable Loss (lowest byte)158) Average Cable Loss95(highest byte)159) Average Cable Loss160) Average Cable Loss161) Average Cable Lo

Page 74 - 284) Reference Level Offset

bit 7 : Not Used168) Status Byte 7: (0b = Off, 1b = On)(LSB) bits 0-1: Not Usedbit 2: DIST-RL Multiple Limit Segment 1 Status On/Offbit 3: DIST-RL Mul

Page 75 - Site Master PM 69

45) Spectrum Analyzer Minimum Frequency Step Size46) Spectrum Analyzer Minimum Frequency Step Size47) Spectrum Analyzer Minimum Frequency Step Size (l

Page 76 - 70 Site Master PM

87) SPA Multiple Upper Limit 1 End Y (Power Level) (lowest byte)88-231) SPA Multiple Upper Limits 2-5, SA Multiple Lower Limits 1-5 (see bytes 72-87 f

Page 77 - Site Master PM 71

bit 4 : SPA Multiple Limit Upper Segment 1 Status On/Offbit 5 : SPA Multiple Limit Upper Segment 1 Beep Level ABOVE/BELOW111bit 6 : SPA Multiple Limit

Page 78 - 72 Site Master PM

Set Spectrum Analyzer Marker to Peak – Control Byte #109 (6Dh) ...86Set Spectrum Analyzer Marker to Center – Control Byte #110 (6Eh)

Page 79 - Site Master PM 73

286) Trigger Type117287) Interference Analysis Frequency118(highest byte)288) Interference Analysis Frequency289) Interference Analysis Frequency290)

Page 80 - 74 Site Master PM

321) Frequency Scale Factor124(higher byte)322) Frequency Scale Factor (lower byte)323) Frequency Range Minimum125(highest byte)324) Frequency Range M

Page 81 - Site Master PM 75

51) Power Meter Relative52) Power Meter Relative53) Power Meter Relative (lowest byte)54) Power Meter Status (00h = Off, 01h = On)55) Power Meter Unit

Page 82 - 76 Site Master PM

137) T1 1stUser Defined Loop Up (lower byte)138) T1 2ndUser Defined Loop Up (higher byte)139) T1 2ndUser Defined Loop Up (lower byte)140) T1 1stUser D

Page 83 - Site Master PM 77

141) E1 1stUser Defined Loop Down (lowest byte)142) E1 2ndUser Defined Loop Down (highest byte)143) E1 2ndUser Defined Loop Down (lowest byte)144) E1

Page 84 - 78 Site Master PM

Select DTF Windowing – Control Byte #31 (1Fh)Description: Select DTF Windowing Methods.DTF windowing allows you to make a trade off between side lobe

Page 85 - Site Master PM 79

3) Current Instrument Date Format1434) Not Used5-11) Model Number (7 bytes in ASCII)12-15) Software Version (4 bytes ASCII)16) Measurement Mode14417-2

Page 86 - 80 Site Master PM

89) Single Limit149(highest byte)90) Single Limit91) Single Limit92) Single Limit (lowest byte)93) Multiple Limit Segment # (1)94) Multiple Limit Segm

Page 87 - Site Master PM 81

189) Cable Loss190) Cable Loss (lowest byte)191) Average Cable Loss155(highest byte)192) Average Cable Loss193) Average Cable Loss194) Average Cable L

Page 88 - 82 Site Master PM

2. gamma3. gamma4. gamma (lowest byte)5. phase158(highest byte)6. phase7. phase8. phase (lowest byte)Notes:return loss = –20* (log(gamma) / log(10))VS

Page 89 - Site Master PM 83

Set T1/E1 Receive Input Configuration Options - Control Word (A013h) (Option 50 only) ...101Set T1/E1 Measurement Duration - Control Word (A014h)

Page 90 - 84 Site Master PM

90) Frequency Marker 3 (lower byte)91) Frequency Marker 4 (higher byte)92) Frequency Marker 4 (lower byte)93) Frequency Marker 5 (higher byte)94) Freq

Page 91 - Site Master PM 85

292) Status Byte 1: ( 0b = Off , 1b = On)(LSB) bit 0 : Marker 1 On/Offbit 1 : Marker 2 On/Offbit 2 : Marker 3 On/Offbit 3 : Marker 4 On/Offbit 4 : Mar

Page 92 - 86 Site Master PM

bit 7: Not Used299) Reference Level Offset173(highest byte)300) Reference Level Offset301) Reference Level Offset302) Reference Level Offset (lowest b

Page 93 - Site Master PM 87

335) Frequency Scale Factor182(higher byte)336) Frequency Scale Factor (lower byte)337) Frequency Range Minimum183(highest byte)338) Frequency Range M

Page 94 - 88 Site Master PM

1. dBm194(highest byte)2. dBm3. dBm4. dBm (lowest byte)For Power Meter Mode (Option 29):57) Power Meter Mode (00h = Off, 01h = On)58) Power Meter Unit

Page 95 - Site Master PM 89

95) Channel Selection (lower byte)96) Frequency Scale Factor201(higher byte)97) Frequency Scale Factor (lower byte)98) Frequency Range Minimum202(high

Page 96 - 90 Site Master PM

79) Pattern Sync Status (00h: In Sync, 01h: Out-of-Sync)80) Carrier Status (00h: In Sync, 01h: Out-of-Sync)81) Rx Alarms (bit 0: Receiving AIS, bit 1:

Page 97 - Site Master PM 91

656) Vpp or dBdsx209(higher byte)657) Vpp or dBdsx (lower byte)658) T1 or E1 Receive Frequency (in Hz)210(highest byte)659) T1 or E1 Receive Frequency

Page 98 - 92 Site Master PM

1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Not enough bytes transferred, “B” trace requested to be used in calculationsor displaye

Page 99 - Site Master PM 93

67) Frequency Marker 2 (lower byte)68) Frequency Marker 3 (higher byte)69) Frequency Marker 3 (lower byte)70) Frequency Marker 4 (higher byte)71) Freq

Page 100 - 94 Site Master PM

Programming OverviewNOTE: This programming manual is written exclusively for Anritsu Site Master Models S331D andS332D. For information on firmware up

Page 101 - Site Master PM 95

170) Relative Propagation Velocity (highest byte)220171) Relative Propagation Velocity172) Relative Propagation Velocity173) Relative Propagation Velo

Page 102 - 96 Site Master PM

188) VNA Signal Standard (lower byte)189-314) Not Used315-1354) Sweep Data (130 points * 8 bytes/point= 1040 bytes)315-2386) (259 points * 8 bytes/poi

Page 103 - Site Master PM 97

66) Scale per div67) Scale per div (lowest byte)68) Marker 1232(higher byte)69) Marker 1 (lower byte)70) Marker 2 (higher byte)71) Marker 2 (lower byt

Page 104 - 98 Site Master PM

254) OCC BW dBc (0-120)255) Attenuation238(highest byte)256) Attenuation257) Attenuation258) Attenuation (lowest byte)259-274) Antenna Name (16 bytes

Page 105 - Site Master PM 99

bit 6 : Multiple Limit Lower Segment 5 Status On/Offbit 7 : Multiple Limit Lower Segment 5 Beep Level ABOVE/BELOW281) Status Byte 7(LSB) bits 0-6: Num

Page 106 - 100 Site Master PM

316) Impedance Loss247(higher byte)317) Impedance Loss (lower byte)318) Frequency Scale Factor248(higher byte)319) Frequency Scale Factor (lower byte)

Page 107 - Site Master PM 101

3. dBm4. dBm (lowest byte)For T1/E1 Modes (Option 50):44) Receive Input (00h: Terminate, 01h: Bridged, 02h: Monitor)45) Framing Mode25946) Line Coding

Page 108 - 102 Site Master PM

86) E Bit Error Count (E1 Only)87) E Bit Error Count (E1 Only)88) E Bit Error Count (E1 Only) (lowest byte)89) Errored Seconds (highest byte)90) Error

Page 109 - Site Master PM 103

Option 6: “6/”Option 10: “10/”Option 21: “21/”Option 29: “29/”Option 50: “50/”If no options are installed: “None”Query Power Level – Control Byte #39

Page 110 - 104 Site Master PM

Power Meter Relative Mode On/Off – Control Byte #41 (29h) (Option 29 only)Description: Enable or disable Power Meter Relative Mode.Bytes to Follow: 1

Page 111 - Site Master PM 105

Exiting Remote ModeTo exit remote mode, send the Exit Remote Control byte #255 (FFh) to the Site Master. The Site Master sends a responsebyte of 255 (

Page 112 - 106 Site Master PM

1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Invalid state238 (EEh) Time-out ErrorPower Meter Center Freq and Span Setup – Control B

Page 113 - Site Master PM 107

Site Master Returns: 17 bytes1-2) Battery Status flags ( Refer to Smart Battery Data Spec 5.1.2.1)3-4) State of Charge (unsigned integer 0 to 100(%)Fu

Page 114 - Programming Examples

224 (E0h) Parameter Error: Invalid trigger level238 (EEh) Time-out ErrorAutomatically Save Runtime Setup – Control Byte #64 (40h)Description: Automati

Page 115 - Site Master PM 109

1-2) Model # (unsigned integer, 14h for Site Master S331D, 15h for Site Master S332D)3-9) Extended Model # (7 bytes in ASCII)10-13) Software Version (

Page 116 - 110 Site Master PM

Write Antenna – Control Byte #82 (52h)Description: Receives an antenna to the Site Master via the serial port.An antenna is described with an index in

Page 117 - Site Master PM 111

5) Antenna Factor (higher byte)6) Antenna Factor (lower byte)Set Field Strength Measurement – Control Byte #84 (54h)Description: Sets the state of the

Page 118 - 112 Site Master PM

Read Channel Power – Control Byte #86 (56h)Description: Read the current channel power or the channel power of a stored trace.Send a 0 (zero) followin

Page 119 - Site Master PM 113

Send a 0 (zero) following the command to read the current adjacent channel power measurement (i.e. the one that is updatedas the unit is sweeping).Sen

Page 120 - 114 Site Master PM

9-12) Low Frequency OCC BW13-16) High Frequency OCC BWMeasure OCC BW dB Down – Control Byte #97 (61h)Description: Measure OCC BW with dB down method.I

Page 121 - Site Master PM 115

Set Spectrum Analyzer Start/Stop Frequency – Control Byte #99 (63h)Description: Sets the spectrum analyzer start and stop frequencies.If Option 6 is i

Page 122 - 116 Site Master PM

Control Byte SummaryControl Byte#Name DescriptionWatchdogTimer1 (01h) Setup System Sets system status flags and switches Yes2 (02h) Set VNA Frequency

Page 123 - Site Master PM 117

3) Ref Level4) Ref Level (lowest byte)5) dB/div (highest byte)6) dB/div7) dB/div8) dB/div (lowest byte)Site Master Returns: 1 byte1) 255 (FFh) Operati

Page 124 - 118 Site Master PM

Set Spectrum Analyzer Peak Hold – Control Byte #105 (69h)Description: Sets the max hold and min hold settings on the Spectrum Analyzer.Bytes to Follow

Page 125 - Parameter Definitions

1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Invalid VBW Index238 (EEh) Time Out ErrorSet Spectrum Analyzer Sweep Mode – Control Byt

Page 126 - 120 Site Master PM

Set Spectrum Analyzer Attenuation – Control Byte #111 (6Fh)NOTE: This command exists for backward compatibility with the S33xC models. Features new to

Page 127 - 925000000 70000000 1025-2023

Site Master Returns: 1 byte1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error: Invalid limit segment, status or value238 (EEh) Time Out Err

Page 128 - 122 Site Master PM

16) Limit Value End X (lowest byte)17) Limit Value End Y273(highest byte)18) Limit Value End Y19) Limit Value End Y20) Limit Value End Y (lowest byte)

Page 129 - VNA Signal Standards

Read Marker Value – Control Byte #117 (75h)Description: Returns the frequency location of the specified marker, and the value at that location.If Opti

Page 130 - 124 Site Master PM

Read InstaCal Module ASCII Serial Number – Control Byte #124 (7Ch)Description: Returns the InstaCal Module serial number in ASCII.Bytes to Follow: 1 b

Page 131 - Site Master PM 125

Check Spectrum Analyzer External Reference – Control Byte #134 (86h)Description: Checks to see if Spectrum Analyzer external reference is present. If

Page 132

1) 255 (FFh) Operation Complete Byte224 (E0h) Parameter Error238 (EEh) Time-out ErrorSet Spectrum Analyzer Resolution Bandwidth – Control Byte #141 (8

Comments to this Manuals

No comments